Flocrete SR200
Previous product
Next product
Flocrete SR200
 

Flocrete
SR100

SHRINKAGE REDUCING ADMIXTURE
 
Advantages:
  • Can be used in air entrained concrete.
  • Minimize the risk of cracking caused by drying shrinkage.
  • Increases the service life of the structure.
  • Does not impact the w/c ratio
Description:

Flocrete SR100 is a shrinkage reducing admixture specially formulated from selected polymers to provide a significant reduction in drying shrinkage and reduce the number of harmful cracks.

Usage

  • Floors and foundations
  • Silos
  • Concrete pipes
  • Walls
  • Watertight construction (i.e. water tanks, swimming pools, etc.)
  • Underground construction

Materials Supplied

Flocrete SR100 is available in 5 gal (19 litre) containers as well as 275 gal (1,041 litre) and 330 gal (1,249 litre) IBC totes. Bulk supply in tanker trucks is also available upon request. 

Shelf Life

  • Flocrete SR100 has a shelf like of 12 months from the date of manufacture when stored at temperatures of 41˚F to 86˚F (5˚C to 30˚C)
  • Below 50°F (10°C), Flocrete SR100 might form small crystals, but these do not affect the properties. If the product has been frozen, it should be thawed out and remixed
  • To avoid discoloration of the liquid and to minimize the risk of deterioration of properties, the product should be stored in plastic tanks or plastic-coated steel tanks
  • Storage tanks should be cleaned annually.

Application Instructions

Flocrete SR100 should be added to the concrete with the mixing water to achieve optimum performance. 

An automatic dispenser should be used to dispense the correct quantity of Flocrete SR100 to the concrete mix.

DOSAGE

Depending on the application, the dosage of Flocrete SR100 varies from 0.5 to 4.0% of the cement or cementitious materials in the mix including GGBFS, PFA or micro-silica.

For the production of a normal flooring concrete, the recommended dosage is approximately 1.0%. Optimum affect is obtained when Flocrete SR100 is added together with the mixing water.

HEALTH AND SAFETY

Flocrete SR100 is not classified as a hazardous material. Flocrete SR100 should not come into contact with skin and eyes.

In case of contact with eyes, immediately flush with plenty of water and seek medical attention.

GENERAL GUIDANCE

This data sheet is for general guidance purposes only and may contain information that is inappropriate for certain conditions of use. Accordingly, all recommendations and suggestions are made without guarantee. Further information is available from our Technical Department.



Download file




Connect with Don Construction Products


  Complaints Record Form

  Customer Satisfaction

Name *
Email *
Phone
Address
Subject
Request  
Security Code *

Don Construction Products Inc.

Headquarters
2826 Lineberger Industrial Dr.
Lancaster, SC 29720

Tel: +1 803 286 5430
Fax: +1 803 286 5432