Hyperplast 150EX
Previous product
Next product
Hyperplast 150EX
 

Hyperplast
150EX

MODIFIED SUPERPLASTICISER FOR EXTENDED SLUMP RETENTION
 
Description:

Hyperplast 150EX is a new generation superplasticizer designed to produce concrete with extended slump retention. This effect can be used to produce low viscosity concrete for mid-to-high scale projects or when pumping concrete over long distances is required.

Usage

  • For concrete pouring at high levels
  • Extended workability concrete for more than 150 minutes
  • Produces high flowability concrete with enhanced compressive strength
  • Structures with congested reinforcement
  • Pre-stressed concrete
  • Improved cohesion allow for use in mass concrete pours and piling
  • Hot weather concreting

Materials Supplied

Hyperplast 150EX is available in 5 gal (19 litre) containers as well as 275 gal (1,041 litre) and 330 gal (1,249 litre) IBC totes. Bulk supply in tanker trucks is also available upon request. 

Shelf Life

Hyperplast 150EX has a shelf life of 12 months from date of manufacture if stored at temperatures between 35˚F and 122˚°F (2°C and 50°C).

Application Instructions

Hyperplast 150EX should be added to the concrete with the mixing water to achieve optimum performance.

An automatic dispenser should be used to dispense the correct quantity of Hyperplast 150EX to the concrete mix.

DOSAGE

The  recommended  dosage  of Hyperplast 150EX is 8 to 85 fl oz/100 Ib (520 - 5,525 ml/100 kg) of cement or cementitious materials in the mix including GGBFS, PFA or micro-silica.

Representative trials should first be conducted to determine the optimum dosage of Hyperplast 150EX to meet the performance requirements by using the materials and conditions in actual use.

EFFECTS OF OVER DOSAGE

Overdosage of Hyperplast 150EX will cause the following:

  • - Significant increase in retardation.
  • - Increase in workability.
Ultimate concrete strength will not be adversely affected and will generally be increased provided that proper concrete curing is maintained.

HEALTH AND SAFETY

Hyperplast 150EX is not classified as a hazardous material. Hyperplast 150EX should not come into contact with skin and eyes.

In case of contact with eyes, immediately flush with plenty of water and seek medical attention.

GENERAL GUIDANCE

This data sheet is for general guidance purposes only and may contain information that is inappropriate for certain conditions of use. Accordingly, all recommendations and suggestions are made without guarantee. Further information is available from our Technical Department.



Download file




Connect with Don Construction Products


  Complaints Record Form

  Customer Satisfaction

Name *
Email *
Phone
Address
Subject
Request  
Security Code *

Don Construction Products Inc.

Headquarters
2826 Lineberger Industrial Dr.
Lancaster, SC 29720

Tel: +1 803 286 5430
Fax: +1 803 286 5432